VL 500 Measurement Head

by Keyence Corp


  • VL-570 | VL 500 Measurement Head
  • VL-570 | VL 500 Measurement Head
Average lead time: Call for Lead Time
ADD TO CART
Need Assistance?

Jump to Section
Product Description
VL 500 Measurement Head
Specifications
Inventory Number:
KYCVL570EA
Part Number:
VL-570
Supplier:
Keyence Corp
Supplier's Lead Time:
Call for Lead Time
Quantity:
1 per EA
Contract Availability:
GSA
Country of Origin:
Japan
Ambient humidity range:
20 to 80% RH (no condensation)
Ambient temperature range:
+ 15 to + 30 Degrees C +59 to + 86 Degrees F
Automatic rotation combined measurements:
Yes
Automatic XY combined measurement range, High magnification (2 × 2 composition):
VL-550: ø110 x H 50 mm ø4.33" x H 1.97"
Automatic XY combined measurement range, High magnification (3 × 1 composition):
VL-550: W 150 x D 70 x H 50 mm W 5.91" x D 2.76" x H 1.97"
Automatic XY combined measurement range, Low magnification (2 × 2 composition):
VL-550: ø500 x H 200 mm ø19.69" x H 7.87"
Automatic XY combined measurement range, Low magnification (3 × 1 composition):
VL-550: W 580 x D 300 x H 200 mm W 22.83" x D 11.81" x H 7.87"
Automatic XY combined measurements:
VL-550: Yes
Control PC:
Dedicated PC specified by KEYENCE (OS: Windows 10)
Controller:
VL-500
Controller Weight:
3.8 kg 8.38 lb
Display resolution:
0.1 µm 0.000004"
High magnification Measurement range:
ø70 x H 50 mm ø2.76" x H 1.97"
Light blocking curtain Weight:
5.5 kg 12.13 lb (VL-550), 3.6 kg 7.94 lb (VL-530)
Load capacity, VL-530:
VL-530: 20 kg 44.09 lb
Load capacity, VL-550:
VL-550: 50 kg 110.23 lb
Low magnification Measurement range:
ø300 x H 200 mm ø11.81" x H 7.87"
Measurement accuracy:
±10 µm 0.0004"
Measurement light source:
Blue LED
Measurement resolution Fine mode (16M Mode):
VL-550: 16 million points
Measurement resolution Standard mode (4M Mode):
4 million points
Measurement Unit Weight:
18.5 kg 40.79 lb
Observation light source:
LEDs in 3 colors (red, green, blue)
Optical receiver system:
Low/high magnification offset dual optical module
Optical transmitter system:
Offset transmission-type projector module
Power consumption, VL-530:
VL-530: Controller/Measurement unit: 200 VA, Stage: 200 VA
Power consumption, VL-550:
VL-550: Controller/Measurement unit: 200 VA, Stage: 80 VA
Power voltage:
100 to 240 VAC ±10%, 50/60 Hz
Repeatability (s):
2 µm 0.000079"
Stage:
VL-550,VL-530
Stage configuration, VL-530:
VL-530: Motorized theta stage mechanism
Stage configuration, VL-550:
VL-550: Motorized XY theta stage mechanism
Stage movement range:
VL-550: ø200 mm ø7.87"
Stage rotation:
360 Degrees (infinite rotation)
Stage Weight:
26 kg 57.32 lb (VL-550), 25.4 kg 56.00 lb (VL-530)
Tilt mechanism:
Up to 45 Degrees
Type:
Measurement unit
Additional Information