Superdex 30 Increase 3.2/300

Supplied by Cytiva


  • 29219758 | Superdex 30 Increase 3.2/300
  • 29219758 | Superdex 30 Increase 3.2/300
  • 29219758 | Superdex 30 Increase 3.2/300
  • 29219758 | Superdex 30 Increase 3.2/300
Average lead time: Call for Lead Time
Need Assistance?

Jump to Section
Product Description

Superdex 30 Increase 3.2/300Improved performance – improved resolution and runtime compared to predecessor Superdex Peptide

Tolerance to repeated harsh cleaning procedures at high pH ensures long column lifetime and minimizes carryover. purity and analysis results

Very high resolution – small bead size and narrow particle size distribution provide high resolution, for high protein purity.

High flow rate – due to rigid beads giving excellent pressure/flow properties.

Superdex 30 Increase SEC columns are for high resolution, smallscale purification and analysis of small biomolecules with Mr ~ 100 to ~ 7000, such as peptides

New generation of size exclusion chromatography columns

Superdex 30 Increase is part of Cytiva's new generation of agarosebased SEC columns called “Increase”, which offer higher resolution purification in shorter runtimes compared with their predecessors.

Specifications
Inventory Number:
GEH29219758EA
Part Number:
29219758
Supplier:
Cytiva
Supplier's Lead Time:
Call for Lead Time
Quantity:
1 per EA
Contract Availability:
Country of Origin:
SWEDEN
Bed Dimensions:
3.2 x 300 mm
Bed Height:
300 mm
Bed Support:
Frit
Bed Volume:
~ 2.4 mL
Chemical Stability:
Conditions where the resin may be operated without significant change in function:
in¢ Trifluoroacetic acid, up to 0.2%
in¢ Isopropanol, up to 5%
in¢ Dithiothreitol (DTT), up to 5 mM
in¢ Acetonitrile, up to 70%
in¢ Formic acid, up to 1
Chemical Stability (Column Hardware):
Resistant to most solutions used in liquid chromatography except hydrocarbons, aromatic solvents, and chlorinated hydrocarbons.
Column i.d.:
3.2
Format_6:
Prepacked column
Matrix:
Composite of cross-linked agarose and dextran
Operating Flow Rate, Max:
0.15 mL/min, water at room temperature;
0.075 mL/min, 20% ethanol or 10% glycerol at room temperature;
0.075 mL/min water at low temperature;
0.035 mL/min 20% ethanol or 10% glycerol at low temperature
Operating Flow Rate, Recommended:
0.075 mL/min
Particle size, d50V:
~ 9 µm
pH Stability Cleaning-in-Place (CIP):
1 to 14
pH stability, operational:
3 to 12
Sample Volume:
4 to 50 µL
Storage Conditions:
4ËšC to 30ËšC, 20% ethanol
Theoretical Plates:
> 38 000 m-1
Typical Pressure Drop Over the Packed Bed:
~ 2 MPa
Additional Information

Contact the GSS Team Today!
GSS-Sales@govsci.com | 800.248.8030 | www.govsci.com

Government Scientific Source
ISO 9001:2015 Certified
Copyright 2026, Government Scientific Source. All Rights Reserved.