Superdex 75 Increase 5/150 GL

Supplied by Cytiva


  • 29148722 | Superdex 75 Increase 5/150 GL
  • 29148722 | Superdex 75 Increase 5/150 GL
Average lead time: 5 to 7 Days
Need Assistance?

Jump to Section
Product Description

Superdex™ 75 Increase 5/150 GLUp to 50% higher resolution compared with predecessor Superdex 75, for improved purity and analysis results.

Runtime reduced down to one third compared with predecessor Superdex 75, with maintained resolution for results faster.

Versatile use in both preparative and analytical applications, especially with recombinant tagged proteins.

Tolerance to repeated harsh cleaning procedures at high pH ensures long column lifetime and minimizes carryover.

Higher lottolot consistency compared with predecessor Superdex 75.

Superdex 75 Increase 5/150 GL is a prepacked column for versatile use in size exclusion chromatography (SEC) applications. The column is intended for rapid purity check and screening of proteins with molecular weights between Mr 3000 and 70 000, such as recombinant tagged proteins. This is the column of choice when time is limited and low buffer and sample consumption is important.

Higher resolution and/or reduced runtime compared with predecessor

Superdex 75 Increase belongs to the new generation of agarose based SEC media, comprising smaller, more rigid beads with a narrower particle size distribution and a higher selectivity for improved performance compared with its predecessor Superdex 75

The column of choice for rapid purity check and quick screeningsThe Superdex 75 Increase 5/150 GL column is well suited for rapid protein purity checks and quick screenings of different experimental conditions (4–50 µl sample volume).Clean in place for versatile useSuperdex 75 Increase medium is alkaliresistant. Hence, the column can be cleaned in place under alkali conditions to allow use of the same column for different proteins with minimal risk for carryover between samples. The alkali resistance is what differentiates agarosebased media from silicabased media. The possibility to the clean the medium under harsh alkali conditions also ensures a long column lifespan.

Specifications
Inventory Number:
GEH29148722EA
Part Number:
29148722
Supplier:
Cytiva
Supplier's Lead Time:
5 to 7 Days
Quantity:
1 per EA
Contract Availability:
Country of Origin:
SWEDEN
Chemical Stability (Column Hardware):
Resistant to most solutions used in liquid chromatography except hydrocarbons, aromatic solvents, and chlorinated hydrocarbons.
Format_6:
Prepacked column
Matrix:
Composite of cross-linked agarose and dextran
Operating Flow Rate, Max:
0.75 mL/min, water at room temperature;
0.35 mL/min, 20% ethanol or 10% glycerol at room temperature;
0.35 mL/min water at low temperature;
0.17 mL/min 20% ethanol or 10% glycerol at low temperature
Operating Flow Rate, Recommended:
0.45 mL/min
Particle size, d50V:
~ 9 µm
pH Stability Cleaning-in-Place (CIP):
1 to 14
pH stability, operational:
3 to 12
Sample Volume:
4 to 50 µL
Storage Conditions:
4ËšC to 30ËšC, 20% ethanol
Theoretical Plates:
> 38 000 m-1
Typical Pressure Drop Over the Packed Bed:
~ 3 MPa