IntelliXcap™ Automated Screw Cap Decapper/Recapper Acoustic 96-format

Supplied by Azenta Life Sciences


  • 46-8014 | IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format
  • 46-8014 | IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format
Average lead time: Call for Lead Time
Need Assistance?

Jump to Section
Product Description

IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format; Includes base unit, IntelliXcheck module and 1 x 48-8013-04 (Acoustic cartridge).

IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format is next-generation, engineered for increased throughput, ease of use and high system reliability, making the system ideal for any laboratory managing compound libraries or biological sample stores working with Azenta Life Sciences Acoustic Sample Tube - Echo® Qualified Consumable

  • Specially designed for use with Azenta Life Sciences Acoustic Sample Tube - Echo Qualified Consumable
  • Also compatible with other 96-format racked tubes
  • Validation of Azenta Life Sciences Acoustic Sample Tube - Echo Qualified Consumable capping and uncapping using rack vision system, done with our Decoding Software and IntelliXcheck module

Azenta Life Sciences IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format is next-generation, engineered for increased throughput, ease of use and high system reliability, making the system ideal for any laboratory managing compound libraries or biological sample stores working with Azenta Life Sciences Acoustic Sample Tube -  Echo Qualified Consumable.

Rapid decapping and capping, compatible with multiple sample storage tube types from a range of tube manufacturers in 96 format. IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format is capable of de-capping a complete rack of 96 tubes in as little as 20 seconds.

Automation and high speed reduces sample handling time, increasing sample throughput workflow. Ideal for medium to high-throughput laboratories managing compound libraries, biobanks or other biological samples.

Additional camera module, equipped in every Azenta Life Sciences IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format, was developed for validation of Azenta Life Sciences Acoustic Sample Tube capping and uncapping by using a rack vision system and Azenta Life Sciences Decoding Software*.

*PC to run Decoding Software not included

Key Features:

Advanced Automation for Increased Throughput:

  • Specially designed for use with Azenta Life Sciences Acoustic Sample Tube - Echo Qualified Consumable
  • Extremely fast, works with multiple sample storage tube types from a range of tube manufacturers
  • Suitable for use with 96-format racked tubes
  • Capable of de-capping a complete rack of 96 tubes in as little as 20 seconds
  • Automation and high speed reduces sample handling time, increasing sample throughput workflow
  • Ideal for medium to high-throughput laboratories managing compound libraries, biobanks or other biological samples
  • Validation of tube capping and uncapping using rack vision system. IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format  is equipped with an additional camera module that uses an image algorithm to detect the presence of caps, before and after the decapping/capping process

Compact, Modular Design for Ultimate Flexibility:

  • Features a unique, fully automated, interchangeable cartridge cap driver system
  • Cartridges allow change between different tube types in less than 2 minutes
  • No need for specialist intervention to change cartridge drivers
  • Control is via a quick installation, easy-to-use touch panel

Easy to Use, Easy to Integrate:

  • Quick installation, easy-to-use touch panels bring instant control
  • Cap detection
  • Wide operating temperature range of 5°C to 40°C
  • Electric torque control means less persistent wear on cap drivers
  • Sample rack stage extension facilitates fully automated workflow integration
.
Parameter IntelliXcap Automated Screw Cap Decapper/Recapper Acoustic 96-format
Dimensions (H x W x D) 316 x 256 x 634mm
Weight 27kg
Stage height 31mm
Stage distance (when ejected) 121mm
Ambient operating temperature 5°C to 40°C (41°F to 104°F)
Capping/decapping speed 20-40 sec to decap or to recap a rack of tubes
Resource Requirements for Decoding Software
Operating ystem Windows 10
CPU Intel i5 or greater
Memory 8GB
Hard disk approx. 250MB free space
Display > 1024x768px

Driver & Cap Compatibility:

  • Azenta provides a wide range of custom made and off the shelf driver cartridges to accommodate your specific labware needs, besides Acoustic Sample Tube - Echo Qualified Consumable
Specifications
Inventory Number:
BKA468014EA
Part Number:
46-8014
Supplier:
Azenta Life Sciences
Supplier's Lead Time:
Call for Lead Time
Quantity:
1 per EA
Contract Availability:
GSA
Country of Origin:
United Kingdom
Additional Information

Contact the GSS Team Today!
GSS-Sales@govsci.com | 800.248.8030 | www.govsci.com

Government Scientific Source
ISO 9001:2015 Certified
Copyright 2026, Government Scientific Source. All Rights Reserved.